Record number: H165149
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/11/02
Date last altered: A98/11/02
Owning B.U.: USA
Abstract: SERVICE PROCESSOR WILL TAKE CONTROL of THE SHARED PORT
SYMPTOM:
If the Service Processor is rebooted using the Netfinity Manager,
the Service Processor will take control of the shared communication port
and this port will no longer be available for use.
If connected to the Netfinity 7000 M10 remotely through a communication port,
upon rebooting the Service Processor the connection will be lost.
PROBLEM ISOLATION AIDS:
FIX:
Next release of the Service Processor code will fix.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.