Record number: H165135
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key: 007
Date created: O98/11/02
Date last altered: A98/11/02
Owning B.U.: USA
Abstract: INCORRECT POWER SUPPLY STATUS, after ADDING a POWER SUPPLY
TEXT:
Adding an extra power supply to Netfinity 7000 M10 causes the
Service Processor to issue an incorrect power supply status.
Recovery message is logged in the event log. This confirms that
power supply is operating correctly.
SYMPTOM:
Upon hot-adding a power supply, the error log will log a power
supply failure in that particular slot together with power supply recovery messages.
Following is the sequence of error messages:
Power Supply x Fault
Power Supply x DC Good Fault
Recovery Power Supply x Fault
Recovery Power Supply x DC Good Fault
PROBLEM ISOLATION AIDS:
WORKAROUND:
Disregard the power supply failure error messages since they are not valid statements.
DETAILS:
These errors will not be generated if the additional power supply is added prior to system power-up.