Record number: H165142
Device: D/T8659
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/11/02
Date last altered: A98/11/04
Owning B.U.: USA
Abstract: NETFINITY 5000: ADAPTER CARDS with PCI BRIDGE (LIMITATIONS)
SYMPTOM:
The Netfinity 5000 server can support up to 4 PCI adapter cards
which contain PCI bridges (e.g. Intel EtherExpress PRO/100 Server Adapter).
If four of these cards are installed in slots 1 to 4 the system will
post the following error message:
00180202 80865200 PCI DEVICE RESOURCE ALLOCATION FAILURE
PROBLEM ISOLATION AIDS:
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.
(For a complete list of Intel trademarks see www.intel.com/tradmarx.htm )
Please see the LEGAL - Trademark notice.