SYMPTOM:

The Netfinity 5000 server can support up to 4 PCI adapter cards which contain PCI bridges (e.g. Intel EtherExpress PRO/100 Server Adapter).
If four of these cards are installed in slots 1 to 4 the system will post the following error message:

00180202 80865200 PCI DEVICE RESOURCE ALLOCATION FAILURE

PROBLEM ISOLATION AIDS:



NOTE: To confirm compatibility see the following Web site:

http://www.pc.ibm.com/us/compat/

FIX:

If using the maximum number of PCI bridge cards allowed on Netfinity 5000 server (i.e. 4 cards), ensure that one of the cards is installed in slot 5.