Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NETFINITY 5000: VRM ERROR - SYSTEM HELD in STANDBY MODE



Subject: NETFINITY 5000: VRM ERROR - SYSTEM HELD in STANDBY MODE
New Netfinity server RETAIN Tip: 

    Record number:       H165117
    Device:              D/T8659
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/11/02
    Date last altered:   A98/11/02
    Owning B.U.:         USA


Abstract: NETFINITY 5000: VRM ERROR - SYSTEM HELD in STANDBY MODE


SYMPTOM:

If the system powers up (fans running) but the power LED is still flashing on the front of the box as if the system were in standby, the system is being held in reset. A Voltage Regulator Module (VRM) error is a prime cause for this.


PROBLEM ISOLATION AIDS:


FIX:

  1.  Check that if VRM is installed, there is an upgrade CPU present. If not, remove VRM.
  2.  Check that if upgrade CPU is present, there is a VRM installed.
  3.  If both VRM and upgrade CPU are installed, replace VRM.
  4.  If problem is still present, replace Planar (suspecting on-board regulator).


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.