Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

UNABLE to UPDATE SERVICE PROCESSOR / POST ERROR 01299181



Subject: UNABLE to UPDATE SERVICE PROCESSOR / POST ERROR 01299181
New Netfinity server RETAIN Tip: 

    Record number:       H164982
    Device:              D/T8660
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/10/21
    Date last altered:   A98/10/21
    Owning B.U.:         USA


Abstract: UNABLE to UPDATE SERVICE PROCESSOR / POST ERROR 01299181


TEXT:

Unable to update Service Processor / POST error 01299181


SYMPTOMS:


PROBLEM ISOLATION AIDS:


WORKAROUND:

Remove all A/C power from server to reset service processor.
Power should be removed for at least 2 Minutes.
Restore A/C and Flash Service processor.
If service processor flash completes, the POST error should go away, and system board and backplane information should be restored.


DETAILS:

System board should not be replaced until an attempt has been made to reset the Service Processor.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.