NETFINITY 5500 M10: ERROR LED RESET to OFF



Subject: NETFINITY 5500 M10: ERROR LED RESET to OFF
Updated PC Server RETAIN Tip: 
Updated Netfinity server RETAIN Tip: 

    Record number:       H164903
    Device:              D/T8661
    Model:               M
    Hit count:           UHC00009
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/10/09
    Date last altered:   A98/12/03
    Owning B.U.:         USA


Abstract: NETFINITY 5500 M10: ERROR LED RESET to OFF


TEXT:

Error LED reset to off.


SYMPTOMS:

Error LED may/will remain "On" if the AC is not removed.


PROBLEM ISOLATION AIDS:


FIX:

Next release of the service processor BIOS for 8661.


WORKAROUND:

After repairing a system problem that was indicated by lit LED on the diagnostic panel, the system should be unplugged for at least 20 seconds so that the error LED can be reset to off.