Record number: H165005
Device: D/T8659
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key: 002
Date created: O98/10/21
Date last altered: A98/10/21
Owning B.U.: USA
Abstract: NETWARE not CONNECTING with 10/100 FAULT TOLERANT ADAPTER
TEXT:
NetWare not connecting with 10/100 Fault Tolerant Adapter
SYMPTOMS:
Incorrect driver will be installed for "IBM Netfinity 10/100 Fault Tolerant Adapter"
resulting in a non-functioning LAN adapter.
PROBLEM ISOLATION AIDS:
Netfinity 5000 server, Type 8659, any Model.
Netfinity 5500 server, Type 8660, any Model.
WORKAROUND:
If your server has an "IBM Netfinity 10/100 Fault Tolerant Adapter" installed,
and the integrated ethernet controller on the system board is disabled, you must do
the following to allow ServerGuide to copy the necessary drivers for the adapter
to properly work:
For the Netfinity 5000 server before using the SoftwareGuide CD:
For the Netfinity 5500 server before using the SoftwareGuide CD:
A jumper on pins 2 and 3 of J5 disables the integrated ethernet.
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.
Please see the LEGAL - Trademark notice.