Record number: H164905
Device: D/T8660
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/10/08
Date last altered: A98/10/13
Owning B.U.: USA
Abstract: REMOTE CONNECTION LOST when RUNNING DIAGNOSTICS
SYMPTOM:
When Netfinity 5500 diagnostics, version 2.00, is run remotely
and "Run Quick Test" is selected the remote connection will be
lost during the test. This occurs when the "Restart Service
Processor Test" runs which resets the remote connection being
handled by the service processor.
PROBLEM ISOLATION AIDS:
FIX:
In diagnostic version 2.01 the "Run Quick Test" will be altered
to not include "Restart Service Processor Test". When this
change is made it will be fine to run "Run Quick Test" remotely.
WORKAROUND:
When running diagnostics remotely do not select the
"Run Quick Test".
DETAILS:
In the "Run Quick Test" of the diagnostics is included a
"Service Processor Test". A subset of the "Service Processor
Test" is a "Reset Service Processor Test". This test will reset
the service processor which is handling the remote connection.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.