Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED



Subject: ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED
New Netfinity server RETAIN Tip: 

    Record number:       H164897
    Device:              D/T8660
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/10/08
    Date last altered:   A98/10/13
    Owning B.U.:         USA


Abstract: ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED


SYMPTOM:

The following Ethernet tests will erroneously report a failure when they are run with an external wrap plug attached to the Ethernet port:

       Ethernet Int 10  MBS Phy Wrap
       Ethernet Int 100 MBS Phy Wrap
       Ethernet Int 100 MBS Twist Wrap


PROBLEM ISOLATION AIDS:


FIX:

With diagnostic version 2.01 these tests will not report erroneous failures with or without an external wrap plug attached to the Ethernet port.


WORKAROUND:

Run the test mentioned without an external wrap plug installed.