Record number: H164906
Device: D/T8680
Model: M
Hit count: UHC00001
Success count: USC0000
Publication code: PC50
Tip key: 003
Date created: O98/10/14
Date last altered: A98/10/14
Owning B.U.: USA
Abstract: REVISION LEVEL of DIAGNOSTICS in SYSTEM SET-UP NEVER CHANGES
TEXT:
Revision level of Diagnostics in system set-up never changes.
SYMPTOM:
Enter system set-up by pressing F1. Select the System
Information option and go to Product Data. This screen should
have the revision level of the Diagnostics. After flashing the
new Diagnostics, go back and check the revision level. It will
remain unchanged until Version 23A.
PROBLEM ISOLATION AIDS:
FIX:
A permanent fix will be available in Diagnostic Version 23A.
WORKAROUND:
There is no workaround until a permanent fix is found. Ignore
the fact that revision level is not being updated since the
code actually gets updated. If you check the system
configuration screen, it will show a new date. Which will
indicate the updated code is installed. Also, the new version
level is viewable if you go to the "About Screen" in diagnostics.