Record number: H164901
Device: D/T8680
Model: M
Hit count: UHC00003
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/10/14
Date last altered: A98/10/14
Owning B.U.: USA
Abstract: POST SHOWS WRONG PROCESSORS AFTER REPLACEMENT of a PROCESSOR
SYMPTOM:
On starting a system, the POST screen will indicate which
processor is the Boot System Processor (BSP) and which is/are
Auxiliary Processor(s) (AP). If a processor has to be replaced
or removed and when the system is powered down and brought up
again, the BSP and AP may return incorrect data.
PROBLEM ISOLATION AIDS:
"Processor x BIST Fail"
FIX:
The next release of BIOS code will fix. BIOS version 24A is
scheduled for October testing and release by 12/98.
WORKAROUND:
If system returns incorrect data on booting, you can get
correct data reported if you do a second reboot of system.