Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PC Server 704 - Parallel Port NOT Functioning in EPP/ECP mode



PC Server 704 - Parallel Port NOT Functioning in EPP/ECP mode

     Record number:       H16849
     Device:              D/T8650
     Date created:        O97/08/12
     Date last altered:   A97/08/20
     Owning B.U.:         USA
 Abstract:PC SERVER 704 PARALLEL PORT NOT FUNCTIONING IN EPP/ECP MODE.
 SYMPTOM:
   Any device attached to the Parallel Port does not work.
 PROBLEM ISOLATION AIDS:
   All of the following must be true for this Tip to apply:
   - The system is a PC Server 704 (8650)
   - The Parallel Port is set to EPP (Extended Parallel Port) or
     ECP (Extended Capability Port).
 FIX:
   Use the following procedure:
   1. Reboot Server, Press <F1> when prompted during POST.
   2. Select "Advanced" from the Menu Bar.
   3. Select "Peripheral Configuration"
   4. Verify Selection of Parallel Port mode.
   5. Select Parallel Port Address <enter>.
   6. Choose the appropriate LPT Port/Address; use the chart below:
      Mode   LPT Port / Address
      _____________________________________
      EPP        LPT3 / 3BCh
      EPC        LPT1 / 378h or LPT2 / 278h
 Note: If the selections are grayed out, verify that the
        Configuration Mode at the top of the Menu is set to
        "Manual" and not "Auto."
   7. Confirm LPT Port/Address choice by pressing <enter>.
   8. Press <F10> to Save and Exit.
   9. Press <Enter> to "Exit Saving Changes"
 Note: The Default Parallel Port Mode setting = "ISA Compatible"
       The Default Parallel Port Address setting = "Disabled"
  Regards, Mark Dunbar