Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PC Server 704 Hangs with PCI Bridge to Bridge Adapters


 Subject: PC Server 704 Hangs with PCI Bridge to Bridge Adapters (8/5/97)
  Geography: ALL, Country: ALL
  Updated PC Server RETAIN/TechTip:
  ------------------------------------
     Record number:       H133573
     Device:              D/T8650
     Model:               M
     Hit count:           UHC00091
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O96/08/07
     Date last altered:   A97/08/05
     Owning B.U.:         USA
 Abstract: PC SERVER 704 HANGS WITH PCI BRIDGE TO BRIDGE ADAPTERS
 SYMPTOM:
   The PC Server 704 Models 8650-4BW, 7AX, and 4M0 trap or hang
   under heavy workload with PCI Bridge to Bridge Adapters
   installed.
 PROBLEM ISOLATION AIDS:
   The IBM Triple LanStreamer adapter (Option p/n 25H6304, FRU p/n
   25H6305) and the Adaptec 3940W and 3940UW are examples of PCI
   bridge to bridge adapters.
   Diagnostics run without error.
 FIX:
   Remove any bridge adapters as they are NOT supported in the
   models 8650-4BW, 7AX, and 4M0.
 Note: PCI bridge to bridge adapters are supported in models
       8650-5M0 and 8650-6MM.  Refer to the following PC Server
       Compatibility WEB page for compatibility information:
       http://www.us.pc.ibm.com/compat/ 
   Adaptec is a trademark of Adaptec, Inc.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.