Record number: H164048
Device: D/T8640 Service code: 33
ECA number: ECA022 Parts source: LOC
EC number: EC000000 Publish flag: R
Mandatory: Y Hit count: UHC00871
Automatic shipment: N Success count: USC0000
Availability date: 98/06 Publication code: PC50
Plant of control: 23 Date created: O98/06/19
Tip key: Date last altered: A99/03/05
Owning B.U.: USA
Abstract: ECA022: FIRMWARE UPGRADE for some 4.5/9.1GB SCSI HARD Drives
PURPOSE:
This ECA is MANDATORY and replaces the previous ECA016.
This ECA provides for a Microcode upgrade on the following IBM SCSI hard drives:
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 76H5817)
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 01K6675)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 76H5818)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 01K6679)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 76H2697)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 93G2970)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 76H2698)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 93G2972)
4.5 GB 50-Pin SCSI Hard Disk Drive (FRU P/N 76H2695)
9.1 GB 50-Pin SCSI Hard Disk Drive (FRU P/N 76H2696)
The Microcode will upgrade these hard drives when attached to the following Adapters / Controllers:
Utility Menu
selection #
ServeRAID Adapter FRU P/N 06H9334 2 or 3
Opt. P/N 70G8489
ServeRAID Adapter FRU P/N 76H6875 2 or 3
Opt. P/N 70G8489
ServeRAID II Adapter FRU P/N 76H3587 2 or 3
Opt. P/N 76H3584
Onboard ServeRAID II Controller (integrated) 2 or 3
PCI SCSI-2 F/W Adapter FRU P/N 06H6473 1
Opt. P/N 94G3771
PCI SCSI-2 F/W Adapter II FRU P/N 06H8574 1
Opt. P/N 94G4673
PCI SCSI-2 U/W Adapter FRU P/N 60H7823 1
Opt. P/N 76H5407
PCI SCSI-2 F/W Controller (Integrated) 1
PCI SCSI-2 U/W Controller (Integrated) 1
Servers eligible for this ECA may exhibit hard drive read errors on the hard drives specific
to this ECA and/or may experience degradation of RAID disk subsystem performance due to read
errors on the drives specific to this ECA and/or may experience defunct drives (DDD) on the hard
drives specific to this ECA.
Drives may be located in the Server or Type 3517,3518,3519,3520 enclosure attached to the
IBM PC Server / IBM Netfinity server.
This ECA is "MANDATORY". This ECA will expire on January 1, 2003
FEATURES:
Type, Machines Affected
Model, With and/or Feature/Device B/M to be Service System
Stage B/M Description Installed Hours Hours
USA:
8638 B/M0000000 PC SERVER 315 B/M0000000 00.5 00.3
8639 B/M0000000 PC SERVER 310 B/M0000000 00.5 00.3
8639 B/M0000000 PC SERVER 325 B/M0000000 00.5 00.3
8640 B/M0000000 PC SERVER 320 B/M0000000 00.5 00.3
8640 B/M0000000 PC SERVER 330 B/M0000000 00.5 00.3
8641 B/M0000000 PC SERVER 500 B/M0000000 00.5 00.3
8641 B/M0000000 PC SERVER 520 B/M0000000 00.5 00.3
8642 B/M0000000 PC SERVER 720 B/M0000000 00.5 00.3
8650 B/M0000000 PC SERVER 704 B/M0000000 00.5 00.3
8476 B/M0000000 NETFINITY 3000 SERVER B/M0000000 00.5 00.3
8644 B/M0000000 NETFINITY 3500 SERVER B/M0000000 00.5 00.3
8660 B/M0000000 NETFINITY 5500 SERVER B/M0000000 00.5 00.3
8651 B/M0000000 NETFINITY 7000 SERVER B/M0000000 00.5 00.3
EMEA: (SAME MODELS)
HOURS PER SYSTEM 0.8
HOURS TRAVEL: 0.8
PHYSICAL CHECK:
Note: Refer to the Adapter List in this Document for FRU P/N's
of Adapters the Update Utility supports.
*********IMPORTANT*********IMPORTANT*********IMPORTANT*********
DAC 960 PL F/W RAID Adapter FRU P/N 75H9011
(PC Server 704 only) Opt. P/N 94G5884
Micro Channel RAID Adapter FRU P/N 06H3059
Opt. P/N 70G9263
Micro Channel SCSI-2 F/W /A FRU P/N 92F0160
Opt. P/N 70G8498
PCI RAID Adapter FRU P/N 06H5078
Opt. P/N 94G2764
***************************************************************
PREREQUISITES:
To Install ECA EC Physical Check
B/M Required Required for Prerequisites
B/M0000000 ECA000 EC000000 NONE
COMPANION:
To Install ECA Machine Comments
B/M Required Type
B/M0000000 ECA012 0000 THE UPDATE UTILITY
PROMPTS FOR THE HARD
DISK IDENTIFY DISKETTE
USED IN ECA012.
LIKEWISE, THE DISK
IDENTIFY DISKETTE USED
IN ECA012 PROMPTS FOR
THE UPDATE UTILITY
DISKETTE.
CONCURRENT:
To Install ECA Machine Comments
B/M Required Type
B/M0000000 ECA000 0000 RETAIN RECORD# H162302
IDENTIFIES A UPDATE
UTILITY THAT IS ONLY
FOR USE ON THE
SERVERAID II ADAPTER.
DETAIL:
Prior to going onsite, download the following diskette images (keep for future use to implement this ECA):
"PC Server and Netfinity server 4.5GB - 9.1GB Hard Drive Update Diskette", V1.04 or later.
(a bootable diskette that contains the Microcode Update Utility for all Adapters listed in this document).
"IBM ServeRAID and IBM ServeRAID II Supplemental Diskette version 2.41" or later (a non-bootable diskette containing
the Network Operating System-specific IPSSEND utilities for use with all ServeRAID II Adapters / Controllers).
These Diskette images may be downloaded from the following URL:
http://www.pc.ibm.com/us/files.html
With the Server up and running:
IPSSEND GETSTATUS X (then press <enter>)
(where X is the Adapter number, example: 1,2,3, or 4)
This will result with the following information displayed:
"Current / Most Recent Operation : = xxxxxxxxx
"Status" : = xxxxxxxxx
Example of Autosynch running:
"Current / Most Recent Operation : = Synchronize
"Status" : = In Progress
Example of Autosynch completed:
"Current / Most Recent Operation : = Synchronize
"Status" : = Completed
Note: The status displayed is that when the IPSSEND command was issued.
The command may need to be re-issued to see any status changes.
DO NOT Start the Microcode Update until the Synchronize Operation is completed.
---------------------- OR ---------------------------------
With the Server down and Powered-Off:
The Microcode Update Utility will automatically check to see if the Autosynch is running.
If it is running, it will return a message indicating Autosynch is running and to run the Update
after it has completed.
To run this Utility, proceed to the next section.
Note:
DO NOT Start the Microcode Update until the Synchronize Operation is completed.
****************************************************************
UPDATING THE MICROCODE ON THE HARD DRIVES:
The Microcode update is executed from the "PC Server and Netfinity server 4.5GB - 9.1GB Hard Drive Update Diskette V1.04"
This diskette is bootable. Upon boot, it will prompt for the user to select from a list of SCSI adapters to load the
respective driver (see the "Utility Menu selection #" column in the Adapter / Controller List for proper Adapter selection).
When the driver loads, the Adapter / Controller will initialize and then the utility will search for the SCSI hard drives
specific to this ECA.
If found, the drive(s) Firmware will be flashed to a new Microcode level (level 64) which fixes the Read error / DDD status issue.
NOTE: DO NOT power off the PC Server / Netfinity server or any attached type 3517, 3518, 3519, 3520 enclosure while
the Update Utility is running.
NOTE: If there are multiple SCSI adapters in the system that are identical, it will not be necessary to run
the update utility for each adapter.
NOTE: If there are multiple SCSI adapters of different types, then the Update Utility needs to be executed more than
one time since the correct driver must be selected at boot time.
The adapters are different and will respond to their respective drivers.
NOTES: This ECA is MANDATORY.
This ECA will expire on January 1, 2003
IBM/TSS CE's should record all time to Service Code 33, ECA022, other office 990.
EMEA Dealers: claim as type 5, referencing CPPS ECA Codes:
Machine Type 8638 = SN
" 8639 = SO
" 8640 = SP
" 8641 = SR
" 8642 = ST
" 8650 = SU
" 8651 = SV
" 8644 = SW
" 8660 = SX
" 8476 = SY
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.