Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ECA017: 325/330 SYSTEM BOARD Replacement for A.S.M.A.



Subject: ECA017: 325/330 SYSTEM BOARD Replacement for A.S.M.A.
New PC Server RETAIN ECA017: 

     Record number:       H163902
     Device:              D/T8639         Service code:      33
     ECA number:          ECA017          Parts source:      LOC
     EC number:           EC000000        Publish flag:      R
     Mandatory:           N               Hit count:         UHC00000
     Automatic shipment:  N               Success count:     USC0000
     Availability date:   98/04           Publication code:  PC50
     Plant of control:    23              Date created:      O98/03/19
     Tip key:                             Date last altered: A98/06/12
                                          Owning B.U.:       USA


Abstract: ECA017: 325/330 SYSTEM BOARD Replacement for A.S.M.A.

PURPOSE:

This ECA provides for the replacement of the System Planar on some PC Server 325 / 330 Systems that are configured with or are being configured with a Advanced Systems Management Adapter. Application of this ECA requires that the System holds true to the Physical Check section in this document.


FEATURES:

   Type,                  Machines Affected
   Model,   With          and/or Feature/Device     B/M to be    Service  System
   Stage    B/M           Description               Installed    Hours    Hours
                          USA:
   8639     B/M0000000    PC SERVER 325 MODELS      B/M0000000   01.5     01.0
                          PTW,PB0,PT0,RB0
   8640     B/M0000000    PC SERVER 330 MODELS      B/M0000000   01.5     01.0
                          PB0, PM0,PT0
                          EMEA:_SAME SYSTEMS:
                          TRAVEL PER SITE: 0.8HR
                          SERVICE
                          PER SYSTEM:      1.5HR


PHYSICAL CHECK:

------ PC Server 325 ----------------------------------------


------ PC Server 330 ----------------------------------------


 +- DIAGRAM A: ----------------------------------------------+
 |                                                           |
 |               < Bar-Code label detail >                   |
 |                                                           |
 |                 Bar-Code                                  |
 |                    |                                      |
 |    ________________|___________________________________   |
 |   |                |                                   |  |
 |   |   |||||||||||||||||||||||||||||||||||||||||||||    |  |
 |   |                                                    |  |
 |   |   XXXXXXXXXXX            XXXXXXX      XX   XXX     |  |
 |   |_______|____________________________________________|  |
 |           |                                               |
 |     serial number                                         |
 |      (11 Char.)                                           |
 +-----------------------------------------------------------+


PREREQUISITES: NONE


COMPANION: NONE


CONCURRENT: NONE


DETAIL:

IF the PC Server 325 meets ALL of the Physical Check criteria (listed for 325), THEN perform the following:

  1.  Backup the CMOS Configuration using the System Utility  Diskette. The Diskette is posted on the IBM Website as:

     " PCServer 325 (8639-PT0, PTW, PB0, RB0) and PC Server 330  (8640-PT0, PB0, PM0) Utility Diskette for Windows NT 3.51 verson 1.30 "

      The IBM Website URL is:

      http://www.pc.ibm.com/us/files.html

     This diskette image file is a self-extracting executable file  that creates a diskette.

     Refer to the readme file on the Diskette for instructions to  backup/restore the System CMOS Configuration.

  2.  Replace the System Planar board with FRU P/N 61H1047  (refer to the Hardware Maintenance Manual Supplement P/N 84H7203).
  3.  Restore the CMOS Configuration using the System Utility Diskette.
  4.  Power up the System to confirm proper System Boot.


NOTE: IF System Boot fails ONLY when configured with the Advanced Management Adapter, AND above steps 1-3 have been applied via this ECA, THEN replace the Adapter using normal warranty replacement procedures.

--------------- OR -------------------------------------

IF the PC Server 330 meets ALL of the Physical Check criteria (listed for 330), THEN perform the following:
  1.  Backup the CMOS Configuration using the System Utility  Diskette. The Diskette is posted on the IBM Website as:

     "PCServer 325 (8639-PT0, PTW, PB0, RB0) and PC Server 330  (8640-PT0, PB0, PM0) Utility Diskette for Windows NT 3.51 verson 1.30"

      The IBM Website URL is:

      http://www.pc.ibm.com/us/files.html

     This diskette image file is a self-extracting executable file  that creates a diskette.
     Refer to the readme file on the Diskette for instructions to  backup/restore the System CMOS Configuration.

  2.  Replace the System Planar board with FRU P/N 61H1044  (refer to the Hardware Maintenance Manual Supplement P/N 10L9158).
  3.  Restore the CMOS Configuration using the System Utility Diskette.
  4.  Power up the System to confirm proper System Boot.


NOTE: IF System Boot fails ONLY when configured with the Advanced Management Adapter, AND above steps 1-3 have been applied via this ECA, THEN replace the Adapter using normal warranty replacement procedures.

NOTES: THIS ECA IS "AS REQUIRED".

THIS ECA WILL EXPIRE FEBRUARY 2, 2004


USA:
IBM TSS CE's should record all time and parts to Service Code 33, ECA017, Other Office 990.


EMEA:
PSS CE's record as above.
Business Partners: Use Warranty Claim 5 (ECA) and quote ECA number: SG (for Type 8639 Server) SH (for Type 8640 Server)
(2 character codes used due to current CPPS restrictions)


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.