ECA007, ECA008, ECA009, ECA011 - PC300/700 - RISER Card



ECA007, ECA008, ECA009, ECA011 - PC300/700 - RISER Card

 Subject: ECA Riser Card - M/Ts 6577/87/89, 6877/87, 8639
          SIGNAL QUALITY CONDITION with PCI TOKEN RING ADAPTER
 AS REQUIRED: CDT PC300/700 6577/87/89, 6877/87 with PCI T/R Adapter.
 MANDATORY:   ALL PC SERVER 310 166MHz = 8639 Mod 0E0,0EV,0EB.
   Dealers should order all needed riser cards (CDT and Server) via UPOS.
 SYMPTOM: The condition can potentially cause a data error that could
   manifest itself in a system hang, or result in incorrect data with or
   without generating an error message.
 PROBLEM: Server 310 166MHz and PC 300 Series 6577 and 6587 systems may
   experience the signal quality condition when used in conjunction
   with either of the following IBM PCI network adapters as listed below.
 FIX: Replacement of the Riser Card to eliminate a potential signal
   quality condition which may occur during file transfer in these
   systems, for PC300/700 only if it contains one of the Token-Ring
   adapters listed below.
 RISER P/N-ECA TABLE:
                                 OLD      OLD           NEW      NEW
 M/T   PRODUCT  ECA   RETAIN   FRU P/N  ASM P/N       UPOS PN  FRU P/N

 6577    PC330  007/  H05712   06H9896  06H9143  3x3  013C073  12J5553
                6577           76H0231  76H6227
 6587    PC350  007/  H05712   06H9899  06H9086  5x5  013C071  12J5554
                6577           07H1266  07H1267
 6877    PC730  008/  H051136  06H9896  06H9143  3x3  013C075  01K2028
                6877           76H0231  76H6227
 6887    PC750  008/  H051136  06H9899  06H9086  5x5  013C074  01K2094
                6877           07H1266  07H1267
 6589    PC365  009/  H055137  07H1266  07H1267  5x5  013C071  12J5554
                6589
 8639    Server 011/  H057094  06H9899  06H9086  5x5  013C072  12J5554
         310    8639           07H1266  07H1267
 ONLY Models 0E0,0EV,0EB = 166MHz Models, with date code below 705 (rear)
 TOKEN RING Adapters:
                        FRU P/N    Mktg PN        Assembly P/N
 IBM PCI Auto           04H8104    OTRPASY or     92G8457 (Original level)
 LANStreamer               or      OTRPAMY or     42H0658
 Token Ring Adapter     42H3377    OTRPATY        42H3279
                                                  55H8985 (Current level)
 IBM PCI Token          41H8874    85H3414 Germ   41H8862
 Ring Adapter                      75H9802 Engl
 CIRCUMVENTION / DETAIL INFO
 SERVER 310 166MHz
 Replace the riser card in 8639 Models 0E0, 0EV and 0EB. System manufac-
 tured after May 1, 1997 (MFG DATE: 705 and later on the rear serial
 number label) are NOT affected.
 PC300/700
 Replace the riser card if BOTH the following conditions are met:
 1) PC 300 Series 6577 or 6587 or PC 700 Series 6877 or 6887 with a riser
    card matching the part number as stated in the table as listed above.
 2) The system contains an IBM PCI Auto LANStreamer Token
    Ring Adapter or an IBM PCI Token Ring Adapter as stated above
 After installing the new riser, place a small white label approximately
 1 centimeter in diameter on the machine type/model label on the rear of
 the system unit. Please obtain a supply of stickers locally. Remarketers
 should also place a sticker on the external shipping label attached to
 the box as well as on the rear of the updated system unit.  Use the
 sticker attached to the rear of the system unit as a means for the
 customer or servicer to identify updated systems prior to an on-site
 service call.
 No other combination of IBM or non-IBM PCI network adapters and
 the PC 300 Series systems or Servers have exhibited this problem.
 EC_TEST.EXE -> Tests the computer (DOS or OS2/W95/NT-DOS-Box) if
   1. It is one of the affected models,
   2. If yes, also for the presence of one the affected T/R Adapters.
 It does not verify the level of the riser card itself.
 This file is available on Internet at:
   ftp://ftp.pc.ibm.com/pub/special/cdtfiles/lccm/ec_test.exe   
 Placement of PCI adapters, especially PCI network adapters
 of any brand, should be done beginning with the PCI slot
 at the base of the riser card, closest to the system board.
 Additional PCI adapters should be installed in a bottom to top
 configuration.
 Customers exposed to this potential condition should place the IBM PCI network
 adapter in the slot closest to the system board until the new riser card has been
 installed. This will minimize the possibility of this condition.
 Service Code: 33