Altered copy Original record number: H057370
Record number: H163011
Device: D/T8640
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O97/11/20
Date last altered: A98/03/12
Owning B.U.: USA
Abstract: PC SERVER 330: INTERMITTENT RAID PROBLEMS
SYMPTOM:
The System is experiencing INTERMITTENT RAID problems.
PROBLEM ISOLATION AIDS:
All of the following must be true for this TIP to apply:
FIX:
x x x x x Y Y Y x x x
IF characters YYY are any of the following combinations,
7AI, 7AJ, 7AK, 7AL, 7AM, 7AN, 7AO, 7AP, 7AQ, 7AR, 7AS, 7AT, 7AU or 7AV
THEN replace the planar with FRU P/N 60H8109 using normal
warranty parts replacement procedures.
Note: If replacing the planar does not resolve the problem,
continue with normal problem determination procedures.