Abstract: SERVERAID II ADAPTER SHIPS WITH HARD DRIVE FLASH DISKETTE
TEXT:
Recent IBM product testing has shown that some IBM 4.5 GB and
9.1 GB Hard Drives might not perform to IBM quality standards
due to possible Read Errors.
A degradation in performance may be observed if these drives
are attached to the ServeRAID II adapter due to Read errors at
the drives that the adapter detects and subsequently will direct
reads to the other drives and rebuild the data on the remaining
drives in a Logical RAID 1, or 5 array.
Read errors may be experienced in Logical Raid 0 arrays.
The ServeRAID II Adapter (when purchased as a option) ships with
a hard disk drive update utility package that contains a Update
Utility Diskette and a 5 page instruction booklet. The Update
Utility is only used to flash the microcode on the following
drives that may be attached to the ServeRAID adapter:
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 76H5817)
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 01K6675)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 76H5818)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU P/N 01K6679)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 76H2697)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 93G2970)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 76H2698)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU P/N 93G2972)
4.5 GB 50-Pin SCSI Hard Disk Drive (FRU P/N 76H2695)
9.1 GB 50-Pin SCSI Hard Disk Drive (FRU P/N 76H2696)
The Utility update diskette is bootable. Upon boot, it will
load drivers for the ServeRAID II adapter and search for the
presence of any of the above listed drives attached to the
SCSI bus. Once found, the drive(s) Firmware will be flashed
to a new microcode level (level 63) which fixes read error
issues.
All currently manufactured drives have been flashed to Firmware
level 63.
NOTE: See the readme.txt file on the Utility update diskette for
instructions on use of the Utility as well as procedures
required to verify the microcode on the listed drives.
The Update utility is located on the IBM Website listed as:
"4.51/9.1 GB ServeRAID II hard disk drive update utility
version 1.00". The URL is:
http://www.pc.ibm.com/us/files.html
Please see the LEGAL - Trademark notice.