Record number: H164870
Device: D/T8660
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/10/07
Date last altered: A98/10/07
Owning B.U.: USA
Abstract: NETFINITY 5500 & 5500-M10: NETWARE 4.11 SMP INSTALL PROBLEMS
SYMPTOM:
During the Novell NetWare 4.11 SMP installation, the problem
will appear as either an inability to see the NetWare
partitions, or a red screen stating that the drives are
inaccessible during NetWare volume creation.
PROBLEM ISOLATION AIDS:
a Netfinity 5500, Type 8660, any Model.
a Netfinity 5500 M10, Type 8661, any Model.
FIX:
Ensure the disk controller on which NetWare is being installed
does not share the IRQ with any other adapter. Install Support
Pack 5B before loading SMP support. Support Pack 5B has a newer
version of MPS14.PSM which fixes the problem.
DETAILS:
The problem is caused by an interrupt routing problem in the
MPS14.PSM module that occurs when the following conditions are met:
The problem does not occur with NetWare 3.x or NetWare 5.0 or
after Support Pack 4 or later (IWSP4.EXE or IWSP5B.EXE) are
applied to the NetWare 4.11 system.
TRADEMARKS:
Other company, product and service names may be the trademarks
or service marks of others.
Please see the LEGAL - Trademark notice.