Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NETFINITY3000: SERVERAID 3X are ONLY SUPPORTED in PCI SLOT 3



Subject: NETFINITY3000: SERVERAID 3X are ONLY SUPPORTED in PCI SLOT 3
Updated Netfinity server RETAIN Tip: 


Subject: NETFINITY 3000: SERVERAID 3X ONLY SUPPORTED IN PCI SLOT-3
Updated Netfinity server RETAIN Tip: 

    Record number:       H164701
    Device:              D/T8476
    Model:               M
    Hit count:           UHC00070
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             003
    Date created:        O98/08/31
    Date last altered:   A99/08/11
    Owning B.U.:         USA


Abstract: NETFINITY 3000: SERVERAID 3X ONLY SUPPORTED IN PCI SLOT-3


TEXT:

Netfinity 1000/3000: Mechanical fit concerns with ServeRAID.


SYMPTOMS:



Note: PCI slot-3 is the farthest away from the motherboard.


PROBLEM ISOLATION AIDS:


FIX:

  1.  Remove the Adaptec Controller from slot-3.
  2.  Install the desired ServeRAID Controller into slot-3.


If desired, place the Adaptec controller into an available slot.

DETAILS:

The Adaptec card that is normally installed in PCI slot-3 can be installed in PCI slot-2 (middle PCI slot) or PCI slot-1 (PCI slot closest to the motherboard).

Note: When the Adaptec card is in either of these slots (1 or 2), it will not function as the boot device.


TRADEMARKS:

Other company, product and service names may be the trademarks or service marks of others.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.