Record number: H164732
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/09/17
Date last altered: A98/09/17
Owning B.U.: USA
Abstract: MULTIPLE FORE ATM ADAPTERS do NOT WORK with NETWARE DRIVER
SYMPTOM:
When trying to load driver for second card (referred to as ATM
slot = 1), get one (1) of the two (2) following messages:
LOADING MODULE FORENP2E.LAN
4-16-98 2:11:49pm ATMTSM-1.8.6
ATM HSM FORENP2E HARDWARE REGISTRATION FAILED
FORENP2E: atmtsm_hsm_Control error code -3
FORENP2E: Unable to map adapter RAM into NETWARE
Server-4.11-1957 Attempt to reinitialize re-entrant module
failed.
Loading Module FOREFP2E.LAN
Server-4.11-1957 Attempt to reinitialize re-entrant module
FAILED.
FOREMUX: FOREFP2E assigned unit number 1
FOREMUX: Unable to set hardware interrupt
FOREFP2E: Unable to map adapter Ram into NetWare
PROBLEM ISOLATION AIDS:
FIX:
Dual "Fore" adapters work with the FAT drivers (forefp2e.lan,
2/12/98) when the PCI IRQ settings are adjusted so that the
two (2) Fore cards are not sharing an interrupt with anything
else.
This means assigning everything else to one IRQ.
Note: Only 9, 10, and 11 are available to reassign.
Also, when using ServeRAID and the Adaptec devices, the newer .ham
drivers are more compatible than the older .dsk drivers,
when using ForeSystems adapters.
DETAILS:
NetWare 5 will supposedly eliminate this problem.
TRADEMARKS:
Other company, product and service names may be the trademarks
or service marks of others.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.