NETFINITY 3500: OS/2 WARP SERVER SMP V4.0 INSTALL HANGS



Subject: NETFINITY 3500: OS/2 WARP SERVER SMP V4.0 INSTALL HANGS
New Netfinity server RETAIN TIP: 

     Record number:       H164427
     Device:              D/T8644
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O98/02/06
     Date last altered:   A98/08/19
     Owning B.U.:         USA


Abstract: NETFINITY 3500: OS/2 WARP SERVER SMP V4.0 INSTALL HANGS


SYMPTOM:

During installation of OS/2 Warp Server SMP v4.0 from shrinkwrap, the System may Hang during installation of diskette #1.


PROBLEM ISOLATION AIDS:

All of the following must be true for this TIP to apply:


FIX:

Go to the following URL and follow the Netfinity 3500 NOS Installation Instructions for OS/2 Warp Server SMP v4.0.

http://www.pc.ibm.com/support



---------------------- OR -----------------------
  1.  Install Warp 4.0 using ServerGuide 4.0.1 or later.


DETAIL: The problem is that OS/2 Warp uses interrupt 13 for SCSI support during the beginning of the installation. This in combination with the resources that the Ethernet Adapter uses results in the above described symptom. The fix is to use the SCSI Driver for the onboard SCSI Controller during the OS/2 installation which is accomplished using the diskettes described above.

NOTE: ServerGuide version 4.0.1 includes the correct SCSI driver to resolve this issue.