Abstract: CORRECT CONCURRENT DRIVE SPIN-UP on POWER-UP SETTINGS
TEXT:
When more than 6 drives are configured for Concurrent
spin-up on power-up, the RAID drives may appear DDD
then / or the System may shut down after the System has
first powered up.
The maximum number of ServeRAID or ServeRAID II attached
hard drives supported for spin-up on power-up is 6. The
default setting on these Adapters / Controllers is 6 but
results in a maximum of 2 drives per SCSI channel spinning
up at power up of the System.
The following procedure will identify the number of drives
configured for spin-up on power-up by the Adapter/Controller:
DETAILS:
Configuring a ServeRAID or ServeRAID II Adapter / Controller to
spin-up more than 6 drives on power-up of the System can result
in some drives not completing spin-up (resulting in those drives
in a DDD state) and / or the System power supply to shut off
(resulting in the System powering off). This is caused by the
combined power requirement of the System AND spin-up on power-up
of MORE than 6 hard drives, which exceeds the power available
from the System power supply.