Record number: H164212
Device: D/T8644
Model: M
Hit count: UHC00034
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/02/20
Date last altered: A99/08/06
Owning B.U.: USA
Abstract: NETFINITY 3500, 3500-M10: INTRANETWARE ISSUE W/ PCI SLOT-1
SYMPTOM:
The driver for any Adapter configured in PCI Slot #1 (System Slot#2) will not load during
the installation of Novell IntraNetWare 4.11.
PROBLEM ISOLATION AIDS:
a Netfinity 3500-M10 server, Type 8655, any Model.
a Netfinity 3500 server, Type 8644, any Model.
Note: The Netfinity ServerProven Compatibility web page is available from the following URL:
http://www.pc.ibm.com/us/compat/
FIX:
Note: The adapter in PCI Slot #1 (System Slot #2) should not be a LAN adapter.
DETAIL:
PCI slot #1 (System Slot #2) SHARES the interrupt assignment with the integrated Onboard 7895 SCSI Controller.
Novell IntraNetWare has limitations with the sharing of interrupts including the sharing of an interrupt by a LAN and a SCSI device.
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.
Please see the LEGAL - Trademark notice.