Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NETFINITY 3500: 1801 PCI/PNP Errors w/ 2 ServeRAID II



Subject: NETFINITY 3500: 1801 PCI/PNP Errors w/ 2 ServeRAID II
New Netfinity server RETAIN TIP: 

     Record number:       H13423
     Device:              D/T8644
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O98/06/17
     Date last altered:   A98/07/08
     Owning B.U.:         USA


Abstract: Netfinity 3500: 1801 PCI/PNP Errors w/ 2 ServeRAID II

SYMPTOM:



PROBLEM ISOLATION AIDS:


FIX:

Remove all ServeRAID II Adapters configured in the System, disable the Onboard Ethernet Controller, re-install the ServeRAID II Adapters, disable the BIOS on all but one, then enable the Onboard Ethernet Controller using the following procedure:

  1.  With the System powered off, disconnect the Power Cord from the System.
  2.  Open the System side cover and note the ServeRAID II Adapters  with respect to slot locations and attached SCSI cables.
  3.  Remove the SCSI Cables from the Adapters, then remove the Adapters.
  4.  Close the System side cover, re-connect the Power Cord to the System, then Power-up the System.
  5.  Press <F1> when prompted during boot, select "Devices and  I/O ports", select "Ethernet Setup", disable the "Ethernet Support",  save and exit the Configuration/Setup Utility, then Power-off the System.
  6.  With the System powered off, disconnect the Power Cord from the System.
  7.  Open the System side cover, re-install the Adapters that were  removed in step 3, to their original slot locations, then reconnect the  SCSI cables to the adapters as noted in step 2.
  8.  Close the System side cover, re-connect the Power Cord to the System, then Power-up the System.  Upon boot, the System will suggest disabling the BIOS  on all but one of the ServeRAID II Adapters.

  9.  NOTE: If one of the ServeRAID Adapters is the Primary Disk  Subsystem (supports the logical Boot drive), then leave it's BIOS enabled.

     Select "yes" when prompted to disable the unecessary BIOS on the ServeRAID Adapter(s).

  10.  Cold-boot the System, press <F1> when prompted, select  "Devices and I/O ports", select "Ethernet Setup", enable  the "Ethernet Support", save and exit the Configuration/  Setup Utility. The System will now boot normally.


DETAILS:

The standard allocated ROM space in the System for Onboard Controllers and Optional Adapters is exceeded when the BIOS is enabled on two or more ServeRAID II Adapters configured in the System (ServeRAID II Adapter uses more System ROM space when it's BIOS is enabled).

Temporarily disabling the Onboard Ethernet Controller results in less ROM space use allowing the System to boot properly so that the Configuration Setup Utility may be accessed to disable the unnecessary BIOS on more than one ServeRAID II Adapter(s) to be loaded in the allocated ROM space. With this reduction of ROM space use by the additional ServeRAID II Adapter(s), the Onboard Ethernet Adapter may be enabled without the total configuration exceeding the standard allocated ROM space.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.