Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PC SERVER 330: MALFUNCTIONS w/ full length ADAPTER in SLOT 6



Subject: PC SERVER 330: MALFUNCTIONS w/ full length ADAPTER in SLOT 6
New PC Server RETAIN TIP: 

     Record number:       H126380
     Device:              D/T8640
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:             026
     Date created:        O98/07/07
     Date last altered:   A98/07/07
     Owning B.U.:         USA


Abstract: PC SERVER 330: MALFUNCTIONS w/ full length ADAPTER in SLOT 6


TEXT:

The PC Server 330 Type 8640 model PB0, PM0, PT0, 11Y should not be configured with a full-length PCI Adapter in System Slot 6 (closest to the Power Supply).


If a full-length PCI Adapter IS configured in System Slot 6, there is risk of one end of the Adapter touching the DASD Cage which may result in component leads / pins of the Adapter shorting to Chassis ground via the DASD Cage causing malfunctions of the Adapter.


Half Length Adapters are not exposed to this risk therefore preferred in Slot 6.

No problems exist with full-length PCI Adapters fitting into the other 5 System Slots.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.