"DEALER CONFIDENTIAL"
Record number: H13313
Device: D/T8650
Model: M
Hit count: UHC00103
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O97/06/17
Date last altered: A98/07/06
Owning B.U.: USA
Abstract: PC Server 704/330/325/315 may TRAP, HANG, or REBOOT
SYMPTOM:
The PC Server intermittently traps, hangs, or reboots.
PROBLEM ISOLATION AIDS:
This failure has only been observed in a controlled lab
environment under stress tests with elevated temperatures.
One or more of the following SIMMs/DIMMs are installed:
FIX:
Use the following procedure to identify suspect SIMMs / DIMMs:
+-----------------+ - or - +-----------------+
| SEC KOREA | | SEC KOREA |
| ### |<- date code | ###Y |<- date code
| KM44x1610yAK-6 | | KM44x1610yAK-6 |
| | | |
+-----------------+ +-----------------+
x can be "V" for the 3.3v part or "C" for the 5v part.
y can be "0" for FPM part or "4" for EDO part.
If the Server is not experiencing these exact symptoms, then there is no reason to replace the SEC memory even if suspect DRAM modules are found. Continue normal problem determination procedures to isolate the failing application or FRU.