Record number: H163901
Device: D/T8644
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/06/11
Date last altered: A98/06/11
Owning B.U.: USA
Abstract: NETFINITY 3500: POWER SUPPLY may LATCH-OFF running 230VAC
SYMPTOM:
PROBLEM ISOLATION AIDS:
Power Supply FRU P/N Header Code
01K9866 ----------------J14SK or J15AJ
01K9858 --------------------J14BG
12J6001 ----------------J14HO or J14RS
The Barcode label is located on the Power supply and lists
a Header code as follows:
Barcode Label
__________________________________________________
| IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII |
| |
| YYYYYxxxxxx xxxxxxx xxx |
|__________________________________________________|
Y= Header Code (first 5 characters)
FIX:
IF the System meets all the criteria listed in the
"Problem Isolation Aids" section of this document,
replace the Power Supply with either of the following Power Supplies:
FRU P/N 01K9866 (with Header Code J15D1)
FRU P/N 01K9858 (with Header Code J15D0)
Note: The Netfinity 3500 server power supply is NOT
a Customer Replaceable Unit (CRU), thus requiring replacement by a IBM Authorized Servicer.
Customers may contact their local Dealer or call:
1-800-IBM-SERVE for Service by a Authorized IBM Servicer.
DETAILS:
Recent ongoing testing at IBM has determined a limited quantity
of Power Supplies used in the Netfinity 3500 server enter a
"Latch-Off state when supplied with 230VAC resulting in the
Power Supply not Powering-up the System when the Power On/Off
switch is actuated. This may occur infrequently and is limited
to power supplies that have Header Codes listed in the "Problem
Isolation Aids" Section of this document.
World-Wide FRU stock has been purged of the suspect Power Supplies.
NOTE: Systems Powered with 120VAC are NOT affected.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.