Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

A.S.M.A.: Critical Event DIALOUT CODES / DATA



Subject: A.S.M.A.: CRITICAL EVENT DIALOUT CODES / DATA
New PC Server / Netfinity server RETAIN TIP: 

     Record number:       H163827
     Device:              D/T8650
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:             004
     Date created:        O98/05/20
     Date last altered:   A98/06/04
     Owning B.U.:         USA


Abstract: A.S.M.A.: CRITICAL EVENT DIALOUT CODES / DATA


TEXT:

Alphanumeric and Numeric Pager Dialout Information:

When the ASMA (Advanced Systems Management Adapter) forwards Automatic Dialout information to a pager, specific numeric information (for digital pagers), and alphanumeric information (for alphanumeric pagers) will be forwarded.

The information (alert) that is forwarded is dependent on which Automatic Dialout event has occurred.


CRITICAL EVENTS feature the following alphanumeric and numeric data:

   TEMPERATURE
                Text:  Temperature
        Numeric Data:  00
   VOLTAGE
                Text:  Voltage
        Numeric Data:  01
   TAMPER
                Text:  Tamper
        Numeric Data:  02
   MULTIPLE FAN FAILURE
                Text:  Multiple Fan Failure
        Numeric Data:  03
   POWER FAILURE
                Text:  Power Failure
        Numeric Data:  04
   HARD DRIVE FAILURE
                Text:  Hard Drive
        Numeric Data:  05


NON-CRITICAL EVENTS feature the following alphanumeric and numeric data:

   SINGLE FAN FAILURE
                Text:  Single Fan Failure
        Numeric Data:  11
   TEMPERATURE
                Text:  Non-Critical Temperature
        Numeric Data:  12
   POST TIMEOUT
                Text:  Post Hang
        Numeric Data:  20
   OS TIMEOUT
                Text:  OS Hang
        Numeric Data:  21
   APPLICATION
                Text:  Application Logged Event
        Numeric Data:  22
   POWER OFF
                Text:  System Powered Off
        Numeric Data:  23
   POWER ON
                Text:  System Powered On
        Numeric Data:  24
   LOADER TIMEOUT
                Text:  Loader Watchdog Failure
        Numeric Data:  26


NOTE: Not all alerts are supported on all Servers, please refer to the Service Processor Manager for Netfinity User's Guide and / or the System documentation to determine which alerts are supported on a specific Server configured with the ASMA.