Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

A.S.M.A. DIAL-OUT FUNCTION MAY NOT COMMUNICATE ALERT



Subject: A.S.M.A. DIAL-OUT FUNCTION MAY NOT COMMUNICATE ALERT
New PC Server / Netfinity server RETAIN TIP:  

     Record number:       H163746
     Device:              D/T8650
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O98/05/19
     Date last altered:   A98/05/20
     Owning B.U.:         USA

Abstract: A.S.M.A. DIAL-OUT FUNCTION MAY NOT COMMUNICATE ALERT


SYMPTOM:

The Automatic Dialout function of the ASMA (Advanced Systems Management Adapter) dials out, but the receiving numeric or alphanumeric pager does not receive the alert.


PROBLEM ISOLATION AIDS:

All of the following must be true for this TIP to apply:


FIX:

Add one or more commas " , " at the end of the telephone number configured for the "Alert Dialout" function in the "Service Processor Manager". Each comma will cause a 2 second delay(*) from the time that the ASMA completes dialing to the time that the numeric or alphanumeric alert is transmitted.

See the 'Service Processor Manager for Netfinity User's Guide' P/N 05L1468 for setting dialout functions for the ASMA.

The "Service Processor Manager for Netfinity User's Guide" is available in pdf format on the IBM Website at the following

URL: http://www.pc.ibm.com/files

Search on "Service Processor Manager"

(*) The delay time is dependent on the Paging Service receiving the dialout.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.