IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
PC SERVER 325: A.S.M.A. LOGS / REPORTS FALSE FAN FAILURES
Subject: PC SERVER 325: A.S.M.A. LOGS / REPORTS FALSE FAN FAILURES
New PC Server RETAIN TIP:
Record number: H163727
Device: D/T8639
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/05/15
Date last altered: A98/05/18
Owning B.U.: USA
Abstract: PC SERVER 325: A.S.M.A. LOGS / REPORTS FALSE FAN FAILURES
SYMPTOM:
- The ASMA (Advanced Systems Management Adapter) erroneously
reports single fan failures.
- These false fan failures are written to the ASMA Event Log
upon each instance.
- If the Automatic Dial-out Function of the ASMA is configured
to dial-out to a pager or another Nefinity System in the event
of a fan failure, the false fan failures will be interpreted
as real fan failures resulting in the Dial-out function to
be executed and send the alert.
PROBLEM ISOLATION AIDS:
All of the following must be true for this TIP to apply:
- The System is a PC Server 325 Type 8639 model PT0, PBW,
PB0, RB0 that is properly configured with a ASMA
(Advanced Systems Management Adapter) Option P/N 94G7578
(FRU P/N 12J4743) or Option P/N 94G5570 (FRU P/N 76H3234)
- The System is configured with any supported version
of NT Server, OS/2, or NetWare.
- System Diagnostics pass.
- The System experiences the described Symptoms when all
cooling fans are functioning.
- The Advanced Management Adapter is presently at a RAM
microcode level* 12 or below.
(*) The RAM microcode level may be viewed from the
"Configuration Information" section of the "Netfinity
Service Processor" Utility located in Netfinity Manager
(details may be found in step 4 under the FIX section
of this document).
FIX:
- Prior to going onsite, download the "Advanced Systems
Management Adapter Configuration Update Utility and Driver
Diskette ver 2.3" or higher from the IBM Website at the
following URL:
http://www.pc.ibm.com/us/files.html
- Update the ASMA RAM Microcode in one of the following ways:
Local Update (At the Server) *************************************
- Boot to the Advanced Systems Management Adapter Configuration
Update Utility and Driver Diskette ver 2.3 or higher.
- Select the 3rd option "Update Service Processor" then
press <enter>.
- Follow instructions on the screen, when complete press <F3>
to exit. Be sure to cycle power OFF, then ON after exiting
to ensure changes will take effect.
Remote Update(Dialed-in to the ASMA from another computer)*****
Refer to page 38 of "Service Processor Manager for
Netfinity User's Guide" to execute the following 4 steps.
- On the machine that used to dial into the Server,
copy the $80C5102.BIN from the Advanced Systems Management
Adapter Configuration Update Utility and Driver Diskette
ver 2.3 or higher to the NetWare directory.
- Dial into the ASMA adapter and establish connection.
- If the Server to be updated is up and running, access the
"System Power Control" and select "Power off with O/S
shutdown" (the system has to be OFF to apply the update).
- Access "Configuration Information" and click on "Update
Ram Microcode", follow the on-screen instructions.
NOTE: Completion of the Microcode Update will result in a
disconnect of the remote connection to the Server requiring
that a remote connection is re-established to remotely Power
Up the Server.
DRIVER UPDATES:
It is recommended that the ASMA drivers are updated after
upgrading the ASMA RAM Microcode (the ASMA Driver update may
be done locally or remotely).
Local Update (at the Server):
For NT:
- Open a MS-DOS Prompt.
- Rename the existing driver and .DLL by typing the following:
rename c:\winnt\system32\ibmspw.dll ibmspw.aaa
rename c:\winnt\system32\drivers\ibmspw.sys ibmspw.bbb
- Insert the "Advanced Systems Management Adapter Configuration
Update Utility and Driver Diskette ver 2.3 or higher into the
Floppy Drive (A drive).
- Install the new drivers by typing the following:
copy a:\nt\ibmspw.dll c:\winnt\system32\
copy a:\nt\ibmspw.sys c:\winnt\system32\drivers\
- Shutdown and Restart the System.
- Cleanup by deleting the ibmspw.aaa and ibmspw.bbb that were
created in step 2.
For OS/2:
- Open an OS/2 Window.
- Rename the existing driver and .dll by typing the following:
rename c:\os2\ibmspo.sys ibmspo.aaa
rename c:\os2\dll\ibmspo.dll ibmspo.bbb
- Insert the Advanced Systems Management Adapter Configuration
Update Utility and Driver Diskette ver 2.3 or higher into the
Floppy Drive (A drive).
- Install the new drivers by typing the following:
copy a:\os2\ibmspo.dll c:\os2\dll\
copy a:\os2\ibmspo.sys c:\os2\
- Shutdown and Restart the System.
- Cleanup by deleting the ibmspo.aaa and ibmspo.bbb
(that were created in step 2.).
For NetWare (requires local and remote access):
- Login to the NetWare server from a client as Administrator.
- Map a unused drive to the sys:\system directory
- Replace the IBMSPN.NLM on the sys:\system drive with the
IBMSPN.NLM located on the Advanced Systems Management Adapter
Configuration Update Utility and Driver Diskette Ver 2.3 or higher.
- Logout of the Server.
- At the NetWare Server, down, exit, and restart the server.
NOTE: To Update NT and OS/2 remotely , establish a Netfinity-to
-Netfinity connection. Then establish a remote session and
start with Step 2 in the above instructions for NT and OS/2.
NT is a trademark of Microsoft Corporation.