Record number: H163238
Device: D/T8639
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/03/11
Date last altered: A98/03/11
Owning B.U.: USA
Abstract: PC SERVER 325/330: Some SERIAL Port Resource SETTINGs FAIL
SYMPTOM:
Failure of the System Board Serial Port(s) result in various
errors from the Network Operating System and/or Application
attempting to use the Port(s).
PROBLEM ISOLATION AIDS:
All of the following must be true for this TIP to apply:
Port A , Address:2E8h, IRQ:4
Port B , Address:3E8h, IRQ:3
Port A , Address:2E8h, IRQ:3
Port B , Address:3E8h, IRQ:4
Port A , Address:3E8h, IRQ:4
Port B , Address:2E8h, IRQ:3
Port A , Address:3E8h, IRQ:3
Port B , Address:2E8h, IRQ:4
* 4 combinations listed.
FIX:
Port A , Address:3F8h, IRQ:4
Port B , Address:2F8h, IRQ:3
Port A , Address:3F8h, IRQ:3
Port B , Address:2F8h, IRQ:4
Port A , Address:2F8h, IRQ:4
Port B , Address:3F8h, IRQ:3
Port A , Address:2F8h, IRQ:3
Port B , Address:3F8h, IRQ:4
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.