Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NETFINITY 7000 - Diagnostics selects ONLY on ONE Hard Drive



Subject: NETFINITY 7000 : DIAGNOSTICS SELECTS ONLY ONE HARD DRIVE

Nefinity server RETAIN TIP:

     Record number:       H162521
     Device:              D/T8651
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:             003
     Date created:        O98/01/14
     Date last altered:   A98/01/14
     Owning B.U.:         USA


Abstract: NETFINITY 7000: DIAGNOSTICS SELECTS ONLY ONE HARD DRIVE


TEXT:

When Running the "IBM Netfinity 7000 Diagnostics" program from the "Netfinity 7000 system CDROM" on A Netfinity 7000 Type 8651 model TM0/TH0/RM0/RH0, only one of 2 or more Hard Drives configured in the system are selected to be tested in the "Tests" menu device list.

NOTE: The diagnostics program will show 12 hard drives in the device list by default.

WORKAROUND:

To run Diagnostics on other drives present in the system, select the drive from the list of darkened drives by moving the curser to the hard drive, and then press the spacebar.
A Series of 6 questions will be displayed asking to perform destructive tests.

Answering NO to ALL six questions will allow non-Destructive tests to be performed, data on the Hard Drives WILL NOT be destroyed.

Answering YES to ANY of the six questions will allow destructive tests to be performed, data on the Hard Drives WILL be destroyed.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.