NOTE:
a PS/2 8557 system, with an image Adapter/A card
installed, does not require a microchannel memory card
installed to experience the system HANG symptom.
****************** and ******************************
2. the image Adapter/A FRU part number must be one of the
following:
a. P/N 07F4401
b. P/N 07F2481 ( EMEA used P/N 07F2511 )
c. P/N 07F2508
systems containing image Adapter/A card FRU part numbers not
listed above are not affected and are not eligible for this
ECA.
PREREQUESITES:
IBM Personal System/2 Image Adapter/A option diskette
version 1.03, publication number S15F-2240.
DETAIL:
Any PS/2 system configured with an Image Adapter/A and a
microchannel memory adapter may exhibit a system HANG
due to a bus contention or Busmaster problem generated
by the image Adapter/A.
Any PS/2 model 8557 may exhibit a system HANG condition with
an image Adapter/A installed, due to a bus contention problem,
with or without a microchannel memory card installed.
a replacement Image Adapter/A card (FRU P/N 06G8223) will be
provided, at no charge to the customer, for systems that meet
the physical check requirements above.
The Image Adapter/A option diskette version 1.03 must be used
in conjunction with the reference diskette to configure the
new Image Adapter/A card.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.