IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
ECA 066 - Token Ring adapter - EPROM
ECA 066 - Token Ring adapter - EPROM
EPROM change for Token Ring adapter
PURPOSE:
This ECA provides replacement EPROMs for affected 16/4 Token Ring adapters.
Machines AFFECTED
All PS/2 with 16/4 Token Ring adapter
PHYSICAL check:
Affected 16/4 Token Ring adapters can be identified by the
part numbers of the two EPROM modules on the card. If EPROM
part numbers 74F9325 and 74F9326 are present, this ECA is
required.
You can also check for microcode level C24550 by running the
Token Ring diagnostics from the reference diskette. If level
C24550 is present, the affected EPROMs are on the adapter.
DETAIL:
This ECA provides replacement EPROMs for 16/4 Token Ring
adapters meeting the physical check requirements. Systems
with affected 16/4 Token Ring cards may exhibit the following
symptoms:
- Loss of communication between the server and client
- Lost sessions
- Server HANG or lock-up
These symptoms may be intermittent.
Only PS/2 used as servers, and operating with non-IBM Network
software, are affected. Workstations which are not used as
servers do not require this ECA:. Replacement EPROMs are shipped
with installation instructions, and are available by ordering:
FRU P/N 92F9122 - in the USA
FRU P/N 92F9126 - in EUROPE