Error code 00011800 (118 error) will be displayed at POST. The memory
diagnostic must be run at this time to clear the 118 POST error.
The following question will be displayed when the memory diagnostics
are run: "A memory failure has been detected, have you replaced a
SIMM ?" The servicer should reply "yes" to this question.
The memory diagnostic will then test the memory and terminate
with no error detected (the memory is not at fault). The
diagnostic will reset the 118 error which appears at POST.
Only 33 MHz processor board, manufacturing P/N 84F9356, is
eligible for replacement under this ECA:. If the processor
has any other manufacturing part number, this change is already
installed and this ECA is not applicable.