IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
ECA 044 - Artic Portmaster/A
ECA 044 - Artic Portmaster/A
Artic Portmaster Adapter/A RS422 interface board x.21
PURPOSE:
To determine if the Artic Portmaster Adapter/A RS422
electrical interface board should be replaced as described
by this ECA:.
PHYSICAL check:
Check the labels on the modules located in positions U16 and
U17. affected boards will have modules labeled version 1.0.
DETAIL:
Customers using x.21 communication protocol with the RS422
electrical interface board may experience communication
failures.
Order FRU P/N 53F2615 through normal distribution.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.