IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
ECA 030 - 8550 - 031/061 1210 + 1225 errors
ECA 030 - 8550 - 031/061 1210 & 1225 errors
1210 or 1225 errors on 8550 models 031,061
PURPOSE:
Provide instructions to determine if the Dual ASYNC card installed in
an 8550 models 031,061 should be replaced for 1210 or 1225 errors
while running diagnostics.
PHYSICAL check:
Affected Dual ASYNC cards (FRU P/N 34F0008) are identified by locating
raw card P/N 90X8074 (upper left corner) on the component side
of the card.
DETAIL:
Error code 1210 indicates a Dual ASYNC port 1 register test failure.
error code 1225 indicates a Dual ASYNC port 2 register test failure.
Error code 1210 or 1225 may occur while running diagnostics on
an 8550 models 031,061 with a Dual ASYNC card installed. If this
condition exists and the Dual ASYNC card matches the above
mentioned physical check, replace the card (FRU P/N 34F0008).
NOTEs:
Order Dual ASYNC cards through normal distribution.
affected cards should be returned
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.