IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
ECA 020 - 8570 / 10483 errors
ECA 020 - 8570 - 10483 errors
8570 mod A21 and 121 having 10483 POST errors
PURPOSE:
Replace model A21 or 121 fixed disk that falls within
established guidelines in the physical check.
PHYSICAL check:
Model 121 systems with a serial number below 72-9027617 and
model A21 systems with a serial number below 72-6000679 that
contain a 120MB fixed disk with a serial number of cxxxxxxx or
20133643 and below are eligible for this ECA:.
( x = any alpha or numeric number.)
DETAIL:
8570 model A21 or 121 fixed disks P/N 90X9286 within the above
specified serial number range can fail POST or Advanced
Diagnostics with intermittent or solid 10483 POST or 10458.
Advanced Diagnostic errors during or immediately following a
cold Power up routine. All customers will be provided the
option of on-site inspection and/or installation of this ECA:
until february 15, 1990. After february 15, 1990 the ECA:'s
standard service offering will be carry in service. ECA on-site
service will be available to customers with NSD on-site
service contracts for all other customers the ECA will be
installed on a carry in basis.
NOTEs:
The physical check portion of the ECA will be performed at the
customer's request or while servicing the system for any system
failure.
Ensure that the customer has a current system back-up before
replacing the fixed disk.
Systems with a solid 10483 POST errors can not do system back-
ups. The servicer or customer may temporarily eliminate the POST
error and allow the backup program to run with these procedures.
once the error is eliminated it will not reoccur unless the
system is turned off.
Turn the system on, and wait for the normal completion of the
Power on cycle (example: Power on pass word or time date menu).
If the POST error occurs run the above on/off procedure several
times. The starting torque of the drive motor should start the
drive. If the 10483 POST error still occurs the servicer should
turn the Power off, and remove and re-insert the original fixed
disk. The movement caused by the removal and installation process
should cause the fixed disk platter to move. This will eliminate
the POST 10483 error. The disk data can now be backed up by the
customer.
If these procedures do not eliminate the solid 10483 error call
your IBM support center for further information.
Those customers expressing a desire to retain the removed fixed
disk due to security reasons may do so at no cost when utilizing
the following procedure in conjunction with ECA:020.
- Make a photo copy of the BAR code label area of the fixed
disk as indicated in the following figure.
- Cut the ribbon cable that goes from the hda assembly to the
HDA controller card.
- enclose the photo copy and the cable / connector in the FRU
box and return them in lieu of the used parts return (UPR)
fixed disk.
______________________________
| |
| _________________ |
| | 20133643 | | |
| |___________|_____| |
| |
| __________________ |
| |P/N IBM | |
| |FRU P/N | |
| |mod | |
| |made in Japan | |
| |__________________| |
|______________________________|
ribbon cable------>
Back to
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.