 |
IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
1GB Pegasus IDE Hardfile (6050/6070) Data loss / WinNT
(Aug-1995)
Subject: 1Gb Pegasus IDE HardFile on 6050/6070
Problem: Potential data loss with 1Gb H/F running under Win NT.
There exits a possibility of data loss when updating device drivers
due to the write Cache on the 1Gb Pegasus IDE Hardfile. This problem
is actually a Windows NT problem but it can be resolved by disabling
the DASD Cache. All systems are now being manufactured with DASD
Cache disabled in order to avoid this problem.
Solution:
If you replace the 1Gb Hardfile ( FRU P/N 06H6416 )
then you must unsure that the Hardfile jumpers are in the same position
as the Hardfile being removed. Please ensure that jumpers are on
positions 1 and 5. If not, move jumper from position 7 to position 5.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.