IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
TRAP 000e / 256 write-thru cache
PROBLEM - PS/Valuepoint 6384/D, 6382/S, and 6387/T 433DX (486 33 MHz) systems
may experience system hang conditions or TRAP 000E errors with a 256KB write-thru cache
option installed, F/C 5296, option P/N 92G7218 (formerly 60G1625) FRU P/N 92F0398.
Machines AFFECTED - Valuepoint 6384/D, 6382/S, and 6387/T 433dx (486 / 33 MHz)
systems.
SOLUTION - If the failure cannot be recreated with the 256KB cache module removed
replace the 256KB write-thru cache module with the 256KB write-back cache, FRU P/N
92f0400. The 256KB write-thru cache module FRU number (P/N 92F0398) is being
substituted to the 256KB write-back cache FRU number (P/N 92F0400) in the parts system.
there is no performance degradation as a result of this change.
Additional Information - Systems with the 256KB write-thru cache option installed may
hang using any operating system. TRAP 000E errors may be experienced in systems using
OS/2 2.x. PS/Valuepoint advanced diagnostics run without errors.
Remove the 256KB write-thru cache option from the system and attempt to recreate the
failure. If the error can be recreated with the cache module removed, this tip does not
apply.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.