IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Madge smart in 6381 with Quantum HD
PROBLEM - The device driver for the Madge Smart 16/4 ISA client ringnode will fail to
load or the network connections will fail when installed in a 6381 w/ a Quantum 120MB
hard file.
Machines AFFECTED - 6381 with 120MB Quantum hardfile
SOLUTION - The Quantum 120MB hard file results in noise generated on the IOR ISA bus
signal.
SOLUTION - A planar FRU has been released that fixes this problem.
425SX P/N 8G4127
433SX P/N 8G4126
If the Madge Smart 16/4 ISA client ringnode adapter device drivers fails to load or network
connections fail, then check the following conditions
1. the Valuepoint being used is a 6381
2. a 120MB quantum h/f is installed
If the above two conditions are met, then the problem exists. In that case that planar needs
to be replaced with the new FRU.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.