IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
DEC pathworks and 3com EtherLink
PROBLEM - In systems running dec pathworks and the 3com EtherLink III adapter, the
data transfer rate fluctuates and is usually very slow.
Systems AFFECTED - All 6381 machines.
SOLUTION - Three fixes are available to solve this problem:
- The network control program (NCP.EXE) on the client and modify the transmit and
receive pipe quotas. The default is either 1 or 3. if the default is 1, change it to 3. If
the default is 3, change it to 1. This will not solve the problem completely, but it will
help.
- Change the DECNET transport protocol to TCP/IP. The problem is only apparent in the
DECNET transport protocol.
- DEC has some new client drivers that fix this problem. They are available from DEC
(1-800-354-9000).
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.