IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
POST error code 161, 162, 163 on 425sx
PROBLEM - POST error 161, 162, or 163 may appear on some Valuepoint 425SX models.
Systems AFFECTED - 6382/S and 6384/D with 425SX processors and system board FRU
part number 61G3215.
SOLUTION - To determine if there is a problem with your system board perform the
following:
- Power on the system and press F1 during the memory count to enter
the configuration utility.
- Verify the date and time setting in the configuration utility.
reset if necessary. Press escape to save the changes.
- Power the system off. Leave the system powered off for a minimum
of 10 minutes. Power the system back on and allow the system to
complete post.
- If no 161, 162, or 163 error is evident during POST and the entry
in the configuration reflects the 10 minutes in which the system was
powered off, this information does not apply.
- If the system does POST a 161, 162, or 163 error during POST and
the system board memory SIMM connectors are numbered J18 thru J21
(type 1 system board) this information does not apply.
- If the system does POST a 161, 162, or 163 error during POST and
the system board memory SIMM connectors are numbered J19 thru J22
(type 2 system board) this information does apply.
- If the system meets the criteria in #6, measure the battery
voltage. This voltage should be approximately 3 volts. If the
battery voltage is not correct then replace the battery.
- If the battery voltage is correct and the system meets the criteria
in #6 then replace the system board with FRU # 61G3215
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.