Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Config utility show 66 MHz instead 60 MHz



PROBLEM - The configuration utility may show the processor speed to be 66 MHz instead of 60 MHz.

Systems AFFECTED - 6384 P60/D, models 188 and 189.

SOLUTION - If the configuration utility shows 66 MHz, locate jumper J7A1. This jumper is located on the left edge of the system board, in front of the video memory controller. verify the jumper configuration is as follows:


jumper position

---------------

i x 60 MHz

x=jumper installed

i x i=open, not jumpered

i i 66 MHz



Additional Information - verify the customer has not modified the base system
configuration with a 66 MHz pentium processor option.


More INFORMATION / HELP is available at the  IBM-HelpCenter