Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Token Ring 16/4 adapter II (P/N 03F0215)



PROBLEM - The Token Ring network 16/4 adapter II (P/N 03F0215) when installed in a in a 6381 will hang while attempting to remote program load OS/2 version 2.x from an OS/2 lan server. Servers with an IBMLAN\RPL\DOS\RPLBOOT.SYS date prior to 9/10/93 will experience this problem.

Machines AFFECTED - All 6381 machines.

SOLUTION - A new version of the RPLBOOT.SYS is required to fix this problem. This can be obtained by contacting OS/2 technical support and reference APAR IC05982.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.