IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Wrong colors after system power up
PROBLEM - Wrong colors on the display after system power up.
Machines AFFECTED - All 6382/S, 6384/D, and 6387/T's.
SOLUTION - A relatively quick (less than 5 seconds between power off and power on)power
off/power on cycle is the most likely sequence that will cause the problem. The system
riser card has been modified to eliminate the failure. The FRU numbers of the updated riser
cards are:
6382: P/N 61G3183 or 61G3164
6384: P/N 61G3185 or 61G3167
Additional Information - N/A
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.