Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

4-mm Tape Cleaning Procedure



4-mm Tape Cleaning Procedure

Feb-97

See > Intermittent 4/10GB Tape Errors

 SYMPTOM:
  The amber Disturbance light (lightning bolt symbol) on the IBM
  4/10GB 4MM DAT Tape drive option flashes or remains on
  continuously.
 PROBLEM ISOLATION AIDS:
  The tape drive is one of the following 4/10GB 4mm DAT Drives:
  FRU P/N      Option P/N
  -------  ------------------
  16G8454  8191359 or 74G8631
  16G8456  8191339 or 74G8632
 FIX:
   1. If the amber Disturbance LED is on solid, clean the drive
      one(1) time.  An internal cleaning algorithm calculates
      when the drive needs to be cleaned and turns on this LED.
   2. If the Disturbance light is FLASHING, clean four(4) times.
 Note: If the Disturbance light continues to FLASH after the
         cleaning AND after a system reset, replace the tape drive.
   The following are additional tape cleaning recommendations:
   1. Clean the tape drive after every 24 hours of tape operation.
   2. Increase the frequency of tape cleanings when new tapes are
      used.
   3. Clean the tape drive one(1) time before any FULL backup or
     after any tape backup failure.
  Customers are responsible for cleaning the tape drive with a
  cleaning cartridge.  Customers may order this cartridge as
  FRU P/N 21F8763