SIMM/DIMM Memory Errors



  PC-Doctor
SIMM/DIMM Memory Errors

SIMM/DIMM error messages issued by the IBM Enhanced Diagnostics:

Message Failure Found Recommended
Actions
2xx-1y A memory error was detected in
SIMM socket Y
Replace the SIMM in the socket
identified by the last digit
of the error code.
Rerun the test.
If the same error code occurs
again, replace the system
board.
2xx-2y A memory error was detected in
DIMM socket Y
Replace the DIMM in the socket
identified by the last digit
of the error code.
Rerun the test.
If the same error code occurs
again, replace the system
board, or where memory is on
the processor card, replace
the processor card.
Corrupt BIOS Information in BIOS is not
as expected.
Not able to find expected DMI
information from BIOS.
Memory controller chipset
vendor ID does not match
expected value.
Reflash the BIOS.
Replace the system board.
Test aborted
by user
User stopped test. Restart test.


NOTE: 'Y' is the SIMM/DIMM socket number. Use the System Board Layouts section (PC300/700, Intellistation), to reference the memory sockets.