IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Compatibility Mode
Centronics/Compatibility Mode
This mode defines the protocol used by most PCs to transfer data to a printer. It is
commonly called the 'Centronics' mode and is the method utilized with the standard
parallel port. In this mode, data is placed on the port's data lines, the printer status is
checked for no errors and that it is not Busy, and then a data Strobe is generated by the
software to clock the data to the printer. Figure 1 describes this transfer.
Compatibility Mode phase transistions:
- Write the data to the data register
- Program reads the status register to check that the printer is not BUSY
- If not BUSY, then Write to the Control Register to assert the STROBE line
- Write to the Control register to de-assert the STROBE line
As can be seen, in order to output one byte of data it requires four I/O instructions
and at least as many additional instructions. The net effect of this is a limitation on the
bandwidth capabilities of the port on the order of 150K bytes per second.
This bandwidth is sufficient for communicating with dot matrix and many older
laser printers, but a limitation when communicating with pocket LAN adapters, removable
disk drives, and the newest generation of laser printers, to name a few. Of course, this
mode is for the forward channel only and must be combined with a reverse channel mode
in order to have a complete bi-directional channel.
This mode was included as a way to provide backward compatibility with the huge
base of installed printers and peripherals. The other modes are used to provide the reverse
channel and high performance communication links.
Many of the integrated 1284 I/O controllers have implemented a mode that uses a
FIFO buffer to transfer data with the Compatibility mode protocol. This mode is referred
to as 'Fast Centronics' or 'Parallel Port FIFO Mode'. When this mode is enabled, data
written to the FIFO port will be transferred to the printer using hardware generated strobes
for the handshaking. Since there is very little latency between transfers, and the software
does not have to do any of the strobing or handshake checking, data rates over 500K bytes
per second are achievable with some systems. This mode, however, is not an IEEE 1284
defined mode and is not described in the standard.
Back to
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.